Please note; All electrical installation and repair work should be carried out by a qualified electrician in accordance with current local codes or regulations.
We're glad the problem's been solved.
Please let us know if there's anything else we can help you with.
Check that other appliances in the room are working, such as other lights, air conditioning, fans/heaters etc.
This is likely to be an issue with the electrical supply and will need to be resolved by an electrician.
We're glad the problem's been solved.
Please let us know if there's anything else we can help you with.
Only check the light if it is safe to do so. If there is any doubt please contact an electrician or maintenance personnel.
This is likely to be an issue with the electrical supply and not related to machine itself.
This issue should be resolved by an electrician.
Turn off the light and remove power supply. Ensure that there is no power to the light before removing the fuse.
Turn the meter on and set it to OHMS.
Put one lead on each end of the fuse and check the display on the meter.
Please note; All electrical installation and repair work should be carried out by a qualified electrician in accordance with current local codes or regulations.
The DALI (Digital Addressable Lighting Interface) is a data protocol and transport mechanism. The common platform of DALI enables equipment from different manufacturers to be connected.
In this instance, we use this as a lighting management control system.
We need a little more information to help us solve your issue.
Please contact our customer service team on 0800 298 0298.
Our experts are ready to help you.
UK based helpline open
8:00am- 8:00pm Monday to Friday
8:00am- 6:00pm Saturday and Sunday
Please disconnect the DALI system. If the light is operational it should power on.
You may need to speak to your DALI engineer to resolve this issue.
We need a little more information to help us solve your issue.
Please contact our customer service team on 0800 298 0298.
Our experts are ready to help you.
UK based helpline open
8:00am- 8:00pm Monday to Friday
8:00am- 6:00pm Saturday and Sunday
As the light is working when the DALI is not connected it is likely to be an issue with the DALI system.
Please contact a DALI engineer to resolve this issue.
We need a little more information to help us solve your issue.
Please contact our customer service team on 0800 298 0298.
Check that other appliances in the room are working, such as other lights, air conditioning, fans/heaters etc.
Analogue dimming - this is usually referred to as 1-10v dimming.
DALI - A lighting management control system.
AC mains/TRIAC - AC/TRIAC dimmers are designed for resistive loads such as incandescent or halogen lights. These phase controlled dimmers are not compatible with LEDs since LEDs do not appear as a resistive load.
Please consult an electrician as to whether the light has been installed with a compatible dimmer.
The product needs to be installed with a compatible dimmer in order to adjust the brightness.
Compatible dimmer - OSram DALI MCU
Analogue dimming - this is usually referred to as 1-10v dimming.
DALI - A lighting management control system.
AC mains/TRIAC - AC/TRIAC dimmers are designed for resistive loads such as incandescent or halogen lights. These phase controlled dimmers are not compatible with LEDs since LEDs do not appear as a resistive load.
Please disconnect the DALI system. If the light is operational it should power on.
You may need to speak to your DALI engineer to resolve this issue.
We need a little more information to help us solve your issue.
Please contact our customer service team on 0800 298 0298.
Our experts are ready to help you.
UK based helpline open
8:00am- 8:00pm Monday to Friday
8:00am- 6:00pm Saturday and Sunday
As the light is working when the DALI is not connected it is likely to be an issue with the DALI system.
Please contact a DALI engineer to resolve this issue.
The light is not compatible with AC/Mains Triac, it will need to be installed with a compatible dimmer in order to dim.
Compatible dimmer - OSram DALI MCU
Please note, a converter is required if an analogue dimmer is being used.
Please disconnect the DALI system. If the light is operational it should power on.
You may need to speak to your DALI engineer to resolve this issue.
We need a little more information to help us solve your issue.
Please contact our customer service team on 0800 298 0298.
Our experts are ready to help you.
UK based helpline open
8:00am- 8:00pm Monday to Friday
8:00am- 6:00pm Saturday and Sunday
As the light is working when the DALI is not connected it is likely to be an issue with the DALI system.
Please contact a DALI engineer to resolve this issue.
The product is not compatible with analogue controls, it will need to be installed with a compatible dimmer, or an analogue to DALI converter, in order to properly function.
Compatible dimmer - OSram DALI MCU
Please consult an electrician as to whether the light has been installed with a compatible dimmer.
This issue can be resolved by reinstalling the light. Cu-Beam Down light is designed to be hung over a table and not used as general lighting for a room.
Please refer to the installation guide.
It is recommended that the lights are installed between 1 and 1.5m from the surface of a table.
We do not advise customers to replace the wires as this will invalidate the guarantee. The wires used are to an exact Dyson specification.
We need a little more information to help us solve your issue.
Please contact our customer service team on 0800 298 0298.
Our experts are ready to help you.
UK based helpline open
8:00am- 8:00pm Monday to Friday
8:00am- 6:00pm Saturday and Sunday
The trim blades are the four plastic blades that connect to the rectangular baffle of the Down light.
To check the blades have been set up correctly, please view the installation guide.
We need a little more information to help us solve your issue.
Please contact our customer service team on 0800 298 0298.
Our experts are ready to help you.
UK based helpline open
8:00am- 8:00pm Monday to Friday
8:00am- 6:00pm Saturday and Sunday
We need a little more information to help us solve your issue.
Please contact our customer service team on 0800 298 0298.
Our experts are ready to help you.
UK based helpline open
8:00am- 8:00pm Monday to Friday
8:00am- 6:00pm Saturday and Sunday
This issue could be caused by the table surface.
Please note, the Cu-Beam downlight is not suitable for use over glass or reflective surfaces.
Analogue dimming - this is usually referred to as 1-10v dimming.
DALI - A lighting management control system.
AC mains/TRIAC - AC/TRIAC dimmers are designed for resistive loads such as incandescent or halogen lights. These phase controlled dimmers are not compatible with LEDs since LEDs do not appear as a resistive load.
The product needs to be installed with a compatible dimmer in order to adjust the brightness.
Compatible dimmer - OSram DALI MCU
Please consult an electrician as to whether the light has been installed with a compatible dimmer.
Your Dyson Cu-Beam light will have been provided with 4m of cable.
We need a little more information to help us solve your issue.
Please contact our customer service team on 0800 298 0298.
Our experts are ready to help you.
UK based helpline open
8:00am- 8:00pm Monday to Friday
8:00am- 6:00pm Saturday and Sunday
We do not advise customers to replace the wires as this will invalidate the guarantee. The wires used are to an exact Dyson specification.
The Dyson Cu-Beam lights are only approved for use with the supplied cable. This cable is to an exact Dyson specification. Replacing the cables will invalidate the guarantee.
How to test a fuse:
Turn off the light and remove power supply. Ensure that there is no power to the light before removing the fuse.
Turn the meter on and set it to OHMS.
Put one lead on each end of the fuse and check the display on the meter.
Please note; All electrical installation and repair work should be carried out by a qualified electrician in accordance with current local codes or regulations.
Fuse type - 4 AMP 250v Fuse.
The installation guide can be found on the above link.
Dyson Cu-Beam Down light 3K (Black)
Contact us
You can quickly access help and advice online – visit our support pages for troubleshooting, how-to videos and more.